Z8
*
Z7
*
Z6
*
Z5
*
Z4Z3Z2Z1
ZONE
CONNECTIONS
AUX
-
+
KPD
K2 K1
BATTERY PROTECTION FUSE:
Replace with a 1.0A/250V fuse
Electronics Line 3000 recommends testing
the system at least once a week. Refer to the
testing procedure found in the user manual.
AUX OUTPUT CURRENT DRAW:
The auxiliary output current allowed
for peripheral units must not exceed
300mA when one keypad is installed.
For each additional keypad (up to 3
max.) the permitted current draw is
reduced by 50mA.
AUXILIARY POWER OUTPUT:
C Operated: 13.5 - 14.0V
Battery Operated: 12V Nominal
AC Transformer
50/60Hz
15VAC
22-30VA
Do not connect to
a switch controlled
receptacle.
LED Keypad
BELL/SIREN OUTPUT:
600mA max.
1 2 3 4 5 6
7
8 9
PGM
10 11 12 14 1513 16
Tamper
Zone
B
L
A
C
K
R
E
D
12V/3.2Ah BATTERY:
Replace the battery
every 3 - 5 years.
The maximum charging
current is 350mA.
+
-
JPD Jumper for factory
default restore
Electronics Line 3000 Ltd. – Penta XL & Penta Plus XL
Household Burglary Alarm Panel
N.C.
2.2K
1
/
4
W
2.2K
1
/
4
W
Typical End
of Line
Resistor
Zone
Connections
(EOLR)
N.C.
-
+
Connector for 3601
Voice Module
7
8
-
+
2.2K
Supervised
Bell
Connections
(USA
hardware
only)
Telephone
Line
Optional
Earth
Connection
2
3
4
5
1
17 18 20 2119 22
J1
J4
ML0109A (6/03)
* Penta Plus XL only
2.2: Wiring Diagram
-7-