-13-
Stay Arming
This feature only arms perimeter zones – i.e. Perimeter, Perimeter with Delay and Fast
Loop Perimeter zones. This allows the user to stay within the protected area while the
system is armed.
To “Stay” arm the system:
1. Check that all perimeter zones are closed; the Ready LED lights up to indicate
that the system is ready to be armed.
2. Press 4, 9.
3. Enter a valid user code; the keypad beeps until the end of the exit delay.
Immediate Arming
Immediate arming allows system arming without an entry/exit delay. Pressing 4 during
the exit delay or when the system is armed cancels both the exit and entry delay times.
Disarming
You can disarm the system by entering a valid user code during the entry delay. If an
error is made when entering the code, press ‘#’ and enter the code again. When the code
is accepted, the Armed LED and the pulsed delay tone are turned off. If the correct code
is not entered by the end of the delay time, an alarm will be generated.
Keyswitch Arming/Disarming
The system can be armed and disarmed using an ON/OFF keyswitch. The keyswitch has
two operation modes.
Latching – closing the keyswitch arms the system, opening disarms the system.
Momentary – opening and closing the keyswitch either arms or disarms the system.
3.5: Distress Keys
In the case of an emergency, 3 types of alarms can be generated by pressing and
holding down the desired distress key for more than 2 seconds. These alarms will send
the relevant distress codes to the central station. The distress keys are as follows:
F
E
P
FIRE: Sounds the fire bell, sends the ‘Fire’ event code to the central station
(address 25) and registers in the Emergency/Trouble event log.
EMERGENCY: Sends the ‘Emergency’ event code to the central station
(address 26), sounds the siren (if programmed at address 01) and registers
in the Emergency/Trouble event log.
POLICE: Sends the ‘Police’ event code to the central station (address 24),
sounds the siren (if programmed at address 01) and registers in
the Emergency/Trouble event log.