ADDRESSES 296-310: EVENT & MESSAGE ROUTING
Event code messages can be routed in several ways. Each telephone number can be set as a primary,
back-up or duplicate number for a specific group of events. The control panel can also be programmed
not to dial a certain telephone number for certain events. A primary number is the first number the
control panel dials when an event occurs. If the control panel is unsuccessful in dialing the primary
number, the back-up number is dialed. A duplicate number is used to report the same event to several
locations and is dialed only after a successful transmission has been made to the primary number.
Routing also determines whether messages are entered in the log, whether the bell is activated and
which bell pattern is sounded.
296-298 Message routing for burglary alarm messages
(alarm, alarm restore, holdup, keypad emergency, police)
296 Message routing for burglary alarms, telephone numbers 4 and 3
Telephone #4
First digit value:
0 - Do not call this telephone number
1 - Primary telephone number
2 - Duplicate telephone number
3 - Backup telephone number
Note: If the Follow-me feature is used, define this number as a duplicate telephone
number.
Telephone #3
Second digit value:
0 - Do not call this telephone number
1 - Primary telephone number
2 - Duplicate telephone number
3 - Backup telephone number
297 Message routing for burglary alarms, telephone numbers 2 and 1
Telephone #2
First digit value:
0 - Do not call this telephone number
1 - Primary telephone number
2 - Duplicate telephone number
3 - Backup telephone number
Telephone #1
Second digit value:
0 - Do not call this telephone number
1 - Primary telephone number
2 - Duplicate telephone number
3 - Backup telephone number
298 Bell Delay, Log Entry and Bell Activation for burglary alarms Select from the following
options to set the 20 second bell delay, log entry and bell activation for burglary alarms.
Bell Delay and Log Entry
First digit value:
0 – No bell delay, no log
1 – Bell delay, no log
8 – No bell delay, log
9 – Bell delay, log
Bell Activation
Second digit value:
0 – No bell
1 – Bell pattern 1
2 – Bell pattern 2
3 – Steady bell
Note: Pulsed signals are available for special alarm types.