21
Bell Cancel
The bell is automatically stopped when the system is disarmed. To stop the bell manually:
1. On the LCD keypad, press SELECT 4, 4; the panel prompts you to enter a user code.
2. Enter an authorized user code; the bell stops ringing immediately and the system sends a Bell Cancel
event code to the central station.
or
1. On the LED keypad, press SELECT 4, 4; the Program LED lights up.
2. Enter an authorized user code; the bell stops ringing immediately, the Program LED turns off and the
system sends a Bell Cancel event code to the central station.
Stop Communications
To stop all communications and clear communication message buffers:
1. On the LCD keypad, press SELECT 4, 5; the panel prompts you to enter a user code.
2. Enter an authorized user code; all communication buffers are cleared and all communications stop
immediately.
or
1. On the LED keypad, press SELECT 4, 5; the Program LED flashes.
2. Enter an authorized user code; the Program LED turns off, all communication buffers are cleared and all
communications stop immediately.
Follow-me
To program a telephone number (telephone #4) for the Follow-me feature:
1. On the LCD keypad, press SELECT 4, 6; the panel prompts you to enter a user code.
2. Enter an authorized user code; the panel prompts you to enter the telephone number.
3. Enter the required telephone number using keys 0 - 9, # to include a three second pause and Q to switch to
tone dialing (DTMF).
or
1. On the LED keypad, press SELECT 4, 6; the Program LED flashes.
2. Enter an authorized user code; the Program LED lights up.
3. Enter the desired telephone number, using keys 0 - 9, # to include a three second pause and Q to switch to
tone dialing (DTMF); after a short delay the Program LED turns off.
Examples: To program telephone number 921-1110 using DTMF dialing, enter Q9211110. To dial telephone
number 9211110 in pulse dialing, and then switch to tone dialing to access extension 231 after a pause, key in
9211110#Q231. Up to 16 digits can be entered, including pauses (#) and tone dialing switches (Q). The Q key
will appear on the display as “T” and the # will appear as “,”.
To disable the Follow-me number enter # (“,”) as the first digit of the number.
Note: Make sure all types of messages that need to be passed to the “follow me” number are routed
correctly (see Chapter Four: Programming). A follow me number can be set on any phone number,
however, only telephone number 4 can be changed through “SELECT” 4, 6.
Late To Close
When using opening/closing windows, the control panel must be armed within the programmed time frame for
the closing window. If the user wishes to stay on the premises and arm the system at a later time, a “Late to
Close” condition can be activated in order to extend the window and prevent a message being sent to the
central station.
To activate a “Late to Close” condition:
1. On the LCD keypad, press SELECT 2, 3; the system prompts you to enter the system number.
2. Enter the system number; the system prompts you to enter a user code.
3. Enter an authorized user code; the system prompts you to set a time.
4. Enter the new closing hour in 24-hour format (HH); the command is acknowledged and the system returns
to normal operation.
or
1. On the LED keypad, press SELECT 2, 3. The Program LED turns on.
2. Enter the system number; the Program LED begins flashing
3. Enter an authorized user code.
4. Enter the new closing hour in 24-hour format (HH). The command is acknowledged, the system returns to
normal operation and the Program LED turns off.